Generac generator runs then shuts off - If you need to go beyond Common Sense Conservation, then turning off the generator for periods of time is another strategy to reduce propane fuel consumption. If the weather is mild and you don’t need power, you can turn the generator off for several hours during the day and then restart your generator to power refrigerators, etc. Alternatively, …

 
Generac Q-55G Highline, model 09592-3, 5500w, 120/240 mounted in 97 Rexhall Aerbus 30ft class A. starts and runs fine. when i push rocker start/stop switch to stop, engine speed lowers but won't stop. when i push rocker start/stop to start, engine goes back to normal. i pulled spark plug wire to stop.. Mohawk updo hairstyles

3. Posted August 10, 2020. 2002 Generac Primpact 66G. Runs perfect, makes power for about 15 minutes and then.appliances, AC etc shut down due.to no power, generatorstill running fine, just not making power. Shut it down for 20-30 minutes, starts back up fine and makes power for 15 minutes, repeat cycle.The generator may have shut down because of overload, which can damage its internal components. In this situation, you need to reset the circuit breakers and power fewer appliances with it. If the problem is not resolved, then there may be something wrong with the generator itself. You should have a Generac Service Dealer inspect it …Generac created the home backup generator category. Today, our generators are preferred by 8 out of every 10 homeowners who invest in home backup power. A permanently installed Generac home backup generator protects your home automatically. It runs on natural gas or liquid propane (LP) fuel, and sits outside just like a central air conditioning ...A generator starts and then dies due to an empty fuel tank, plugged fuel filter, dirty carburetor, clogged fuel line, bad gas cap, dirty spark plug, faulty ignition coil, low engine …Mechanic's Assistant: How long have you been experiencing this issue with your generator shutting off when a load is applied? Since I bought it two weeks ago. Mechanic's Assistant: OK. Thanks for the info. The Generac Small Engine Technician can help with your Generac NP 66 G propane generator shutting off when a load is applied.Good day fellow adventurers. I have a 1997 Lance that came factory equipped with the Generac Impact 34 propane generator. it only has 112 hours on it. I let the camper sit about a year and now when I start the generator it goes directly into a high rev situation and shuts down. All of my electrical goes through the original Magnetek Power plus ...03 - Generac Generator Fuel Cap. As fuel is consumed by the engine, the level in the fuel tank lowers. To make up for this, the fuel cap uses a small vent to allow air to enter the tank. If the fuel cap vent is clogged, air won’t be able to enter the tank and a vacuum or “vapor lock” will occur. This stops the flow of fuel to the ...Need help - generator runs for 5 to 10 minutes then dies Generac Portable Gasoline Generators. Reply. Junior Member 6 posts. norm200 Jun 30, 2015. I have a 2005 Guardian gas generator model 004582 15,000 watts.i cleaned the carb,but it only run for 5 to 10 minuets then die's,it cranks back up does same thing. the generator run's at a high also ...Dec 13, 2019 · The truth is that your generator will start but may cause permanent damage to the engine. Newer generator models, such as Generac, have a “low oil shutoff sensor” automatically shutting off your generator when oil levels are running low. Air Filter . An engine will automatically shut down if it is not receiving enough air from its surroundings. OVERHAUL - Costs about $25 for an overhaul / rebuild kit. REPLACE - Costs about $100. I ultimately chose to go with option #2 because I felt confident that my generator will be working after the engine tuneup (replacing air filter, spark plug, oil change, etc.) + overhauling my carburetor.No lights were lit on the panel. No red trouble lights and no green "system set" light. I pressed the switch to "manual" and the engine started, ran and sounded normal for approximately 15 seconds, then shut itself off, then re-started, ran 15 seconds and shut itself off again. This repeated several times until I pressed the switch to "off".Help. I have a Generac 56060 XP8000 Model generator. After about 20 minutes of run time it shuts off. It starts smoothly and appears to run smoothly. I have tried everything. It has gas and plenty of … read moreIt starts right up, but shuts down around about 8 seconds. I noticed that if the regulator indicator light comes on, it will continue to run and make power. If the regulator indicator light does not come on, it will not make power, and usually shuts down. Occasionally it will continue to run without making power.This wire is grounded when a generator automatically starts after a power loss. The 194 wire provides 12 VDC to the ATS and is always powered. 2. Confirm that the generator's Main Line Circuit Breaker (MLCB) is in the ON position. If this is in the OFF position when the generator is in AUTO mode, then the generator will start, but the ATS will ...FAQs. The transfer switch is an essential part of the home backup system. Its primary function is to prevent your home from being powered by utility and generator power at the same time. If utility power is lost, the generator control panel senses the loss and tells the transfer switch to close off the connection with utility and complete the ...I have a generac generator (0047211) and starts and run fine for a few seconds. Then the starter tries to engage again. It is a 15 kw gen set. The engine revs up as the starter tries to start the already running generator. It is as if the generator does not know it is already running?Turn off the generator and let it cool down. Put on gloves and safety goggles. Open up the generator's cover or panel to get to the carburetor. Spray carb cleaner on all the carb parts. Wait for it to loosen the grime, which usually takes 10 to 15 minutes. Use a brush to scrub away the loosened dirt gently.Sep 6, 2013 · Before the generator's engine starts, there is no oil pressure. The oil. sensor is ignored until the engine has a chance to come up to speed. If. it then shuts down, it normally indicates a low oil level. If you are sure there is enough oil, disconnect the wire to the oil. sensor and see if the engine keeps running. If it shuts down after 4 seconds then it is likely the low oil pressure switch. If it shuts down after 2 seconds, then likely it is the rpm sensor on the flywheel. It can go bad or go out of adjustment. Check the sensor output while running , even if only 2 secs, you should get 0.4-0.6 v AC and the sensor should have 1000 ohms +- 10 % resistance.The generator seems to run indefinitely now, without a load. Before cleaning the slip rings, it would only run for about 2 minutes, max. Then only 10-15 seconds if restarted, then would not start upon repeated attempts. After cleaning the slip rings, it ran for ~20 minutes last Wednesday before shutting itself off.My Generator would shut down with a low oil pressure reading appearing on the control panel. The engine would start but then shut down after some 5-10 seconds. I changed the oil pressure switch with no positive result. I then bought a pressure gauge and put that in place of the oil pressure switch. I got a zero reading on the gauge.Hopefully someone can help me out. I have a 22kw standby Generac (model 0065511, S/N 9700921) that is now four years old and has 55 hours of run time on it. It runs on natural gas. With the storm that just passed, the generator ran for about 35 hours over the past two days. Before the storm, the generator was at 20 hours run time.According to the official Windows support site, a reason why a computer running Windows will not shut down may be that a device driver or program is interfering with the standard s...Posted 12/21/2013 19:43 (#3536955 - in reply to #3536709) Subject: Re: Generac Generator shutting off after startup. Faunsdale, AL. Could be any one of several things, but most likely a bad circuit board, broken wire etc. They will also shut down like that from low oil pressure, (usually has to time out a delay ), no AC voltage build up ...1998 Rexair motor home with a Generac Model #GN480 Q55G serial#301011. Starts easy, runs great for about 1 to 2 minuets, then shuts off. Not low on oil. Generator will run as long as I have 12 volts a … read moreFAQs. The transfer switch is an essential part of the home backup system. Its primary function is to prevent your home from being powered by utility and generator power at the same time. If utility power is lost, the generator control panel senses the loss and tells the transfer switch to close off the connection with utility and complete the ...6. Start the set and let it run. While it is running, measure the output voltage of the set. With these wires disconnected, then engine should run for longer than 5 minutes. Wile carefully monitoring for engine overheating, or any strange noises (shut it off immediately if either are noted), let the engine run for about 10-15 minutes. 7.Honda 5hp 2600 runs good for 20 to 30 min. then shuts off. After waiting 15 to 20 min. engine will start again and repeats the above problem. Oil level is good …Step 4: Press the Enter key. Step 5: Wait 30 seconds. Step 6: Press the blue Manual button on the control panel once. This will let the generator start running the test for 5 minutes. Step 7: Allow it to run the test, and if it doesn’t, put it into the OFF position by pressing the red button.Sorry didn't get the ser#. The unit starts right up and runs fine with or without a load. I ran it for 10 minutes with not 1 backfire. Then I shut it down and attempted to restart. It cranked over good but did not start up. During the cranking I heard it backfire out the exhaust and the intake. I shut the gas off and cycled it to clear it out.We purchased a Generac generator to run off our propane tank. It runs then shuts off. ... 2013 generac generator 20k with a evolution board. recently hooked up start and runs then shut off it 5 seconds. did a test five on it disconnected the j plug reconnected it with the fuse out then re ...Code 33 is High Engine Coolant Temperature. If the genset is only running for 2 minutes, it is obviously not overheating. That means you have a bad temperature sender, and it must be replaced. The temperature sender is screwed into the side of the thermostat housing, and the top cover must come off the genset to access it.If it shuts down after 4 seconds then it is likely the low oil pressure switch. If it shuts down after 2 seconds, then likely it is the rpm sensor on the flywheel. It can go bad or go out of adjustment. Check the sensor output while running , even if only 2 secs, you should get 0.4-0.6 v AC and the sensor should have 1000 ohms +- 10 % resistance.How do I shut down my generator when it's powering my house? +. RPM Sense Loss, Code 1501/1505/1511/1515 +. View All Home Backup Error Codes. Portable Generator …First, ensure the generator is off and disconnected from its power source. Locate the circuit breaker and check if it's in the 'off' or 'tripped' position. If it is, switch it back to 'on'. Start the generator, and if the green light comes on, a tripped circuit breaker is the issue.Experience: Certified on Onan and Generac generators. Verified. Hello! Thank you for choosing Just Answer for the solution to your problem. ... /30502M. at first the engine would not start (has to be started from remote controls) the it would run for a short time then shut off or run with the start but ...My Generac 4000 EXL starts well but then only runs for 5-10 seconds and then stops. It seems like it is starved for fuel. It will start right up again and do the same thing. I can do this over and ove … read moreCustomer has a 25kw liquid cooled generac connected to natural gas from utility. System ran fine for 12+ hours then shutdown. Customer tries multiple times to start and it would run 60 seconds then ramp up to high rpm then shutdown. Whenever I was onsite, same issue. This unit was running due to hurricane Sally. Possibly low gas … A: Check the level gauge on your propane tank regularly. If the tank is emptying much faster than expected based on your generator’s fuel consumption, there may be a leak or other issue. The generator will shut off immediately once the tank runs dry. Q: I just filled my propane tank, but the generator still shuts off after running for a while. It will run in manual for about 10 seconds and then shut down for overspeed again. The engine seems to be running at normal RPM while it's running, but it won't stay running. ... They tore the whole left hand side of the generator off to get to what you had mentioned, the "slip rings". ... Hello, I have a Generac generator model G0070432 Series ...Remove all loads before turning the generator off. First, turn off all appliances, lights, and items being powered by the generator. Then, unplug the items from the generator's receptacles and allow the generator to cool. Once you've done this, it is safe to turn the generator off. NEVER turn the generator off while loads are applied.Gas line will be changed to 3/4 " in to gen, with the Generac vibration line then a 36" x 3/4 pipe to 2nd stage regulator. When gen runs for 10 seconds the flow of gas is 10.5" w.c and the RPM is steadyThe unit hadn't been used for quite a while and wasn't working, but I found the problem to be a bad battery. I replaced the battery and got the unit running. I went through checking the manual operation, then checked out the automating transfer switch operation. Everything worked great and the unit ran well. I then went to set the exercise timer.We purchased a Generac generator to run off our propane tank. It runs then shuts off. ... 2013 generac generator 20k with a evolution board. recently hooked up start and runs then shut off it 5 seconds. did a test five on it disconnected the j plug reconnected it with the fuse out then re ...4. Faulty Spark Plugs. If your Generac generator keeps shutting off, it may be due to dirty or faulty spark plugs. Inspect the spark plugs and clean or replace them if necessary. Spark plugs play a crucial role in igniting the fuel-air mixture and any issues with them can cause the generator to cut out. I have a Generac GP17500E that starts right up, revs up, and then shuts off. This generator may have 1 hour on it. It worked for awhile last winter and then this problem started when I unhooked the battery that was on it. Mechanic's Assistant: Do you have fuel in the tank? If so, is the shut-off valve open and the fuel clean? Some generators are designed to automatically shut off when the fuel level drops to ¼ tank, to ensure that it doesn’t run out. So, make sure it’s filled at least halfway. Over filling the generator will also cause it to run poorly. Fuel Shut Off Valve. Locate and inspect the condition of your generator’s fuel shut off petcock valve.Hello, I have a 12kw Briggs and Stratton generator. which was not putting out voltage. I communicated with Hank from just answer, and during my search and questions and answers found out that the exciter circuit capacitors was connected up wrong.I made the correction and now the generator runs and puts out voltage, but shuts down after a few seconds.The generator then starts up again runs for ...Step-01. Check the Oil Level and Auto Shutoff Switch. An automatic shut off triggered by low oil is one of the most common causes of abrupt 20 minute shutdowns. Begin by checking the oil level with the dipstick. Replenish the oil if it is low. With adequate oil, the issue may be a faulty auto shutoff switch.Aug 21, 2021 ... ... generator before you turn off the generator, and then when you're ready to turn the generator on start the generator first and then connect theNo lights were lit on the panel. No red trouble lights and no green "system set" light. I pressed the switch to "manual" and the engine started, ran and sounded normal for approximately 15 seconds, then shut itself off, then re-started, ran 15 seconds and shut itself off again. This repeated several times until I pressed the switch to "off".This makes it hard for the generator to run smoothly since it tries to match the power needed but its capacity doesn't allow it. Solution. While the generator is still running, shut off some electronics connected to the power from the generator then gauge if the sound changes or not. Keep reducing the load until the generator stabilizes its roar.Im looking for a low oil pressure switch for the generac in my RV. Generator starts and runs for about 10 - 12 seconds then shuts down. I'm assuming it the low oil pressure sensor. Oil and filter are … read moreRPM Sense Loss, Code 1501/1505/1511/1515 -. If the unit was running and shuts down, attempting to restart, clear the alarm by pressing the ENTER button twice, then press AUTO. Next, remove some of the loads. Try putting it back in AUTO and then restart. If it does not start after doing this, you will need to place a service call.Some generators are designed to automatically shut off when the fuel level drops to ¼ tank, to ensure that it doesn’t run out. So, make sure it’s filled at least halfway. Over filling the generator will also cause it to run poorly. Fuel Shut Off Valve. Locate and inspect the condition of your generator’s fuel shut off petcock valve.Generator Only Runs A Few Minutes & Dies - Here's Why!If your generator won't stay running or only runs a few minutes and dies make sure to checkout this vid...There are two ways I usually determine this. One is to check the heat coming off each exhaust pipe on each cylinder. If one is much cooler then the other that cylinder is likely to blame. To further check this I use a pair of insulated pliers and will remove the cold side spark plug wire while the engine is running.Operate the generator on a level surface. 3.) Tipping the Generator While Moving It. Following the principle as stated above, if you excessively tilt your generator while moving it so that the valve cover, breather tube, and air filter go towards the ground, then oil can run up and out. How to Fix:3. Posted August 10, 2020. 2002 Generac Primpact 66G. Runs perfect, makes power for about 15 minutes and then.appliances, AC etc shut down due.to no power, generatorstill running fine, just not making power. Shut it down for 20-30 minutes, starts back up fine and makes power for 15 minutes, repeat cycle.Have Enough Fuel Available. Even if your generator is ready to run, you'll need enough fuel to keep it going in the event of a prolonged outage. Keep at least 10 gallons of fresh gasoline for ...1. Set the main utility disconnect to OFF (OPEN). 2. Set the generator MLCB (generator disconnect) to OFF (OPEN). 3. Allow the generator to run for a cool-down period of …One of the most common issues to plague generator owners is the dreaded "surge" or "revving up and down" of the engine. This can happen when the generator is under load or when it's simply at idle. As a general rule, a portable generator will surge at idle due to a clogged or restricted pilot jet on the carburetor.So, fasten your seatbelts—let's illuminate the shadows of "Generator Shuts off After 20 Minutes" together! Generator Shuts off After 20 Minutes. When a generator shuts off after 20 minutes, several issues could be causing this problem. Overheating: Generators can overheat if they operate for extended periods without proper cooling.Sep 5, 2021 ... Generac Generator Over Crank Easy Fix. HVACR ... Generac Generator Won't Start RS8000E ... Generator Runs A Few Minutes & Dies - Here's Why!It will start and run for about 10 seconds and then shut down. It says rpm sense - Answered by a verified Technician ... i have a generac 20kw generator model#58751 serial #7386536. that when it starts it goes to very high speed and runs for about 10 seconds and shuts down and has on the screen rpm sense loss ... the generator starts and won't ...If so, verify proper installation. Ensure fuel is turned on. A shutoff valve should be within 6ft of the unit. Verify fuel lines have been bled. Air pockets in the line will prevent the unit from starting, this is especially common if LP was recently refilled. Check for an empty or low LP tank. Verify proper fuel conversion if running on LP.Turned auto idle off, restarted fine. I put a load on it (120V 2 hp Air Compressor), it took it fine. Until the compressor turned off, then so did the generator (auto idle still off). Now the generator starts up, runs to what appears to be a higher than normal RPM, puts out a no load 120v voltage of around 42V and shuts off.Turn off the generator, then turn off the choke, and restart it. If the problem persists, you should consult a mechanic. ... Moreover, it comes with automatic "low oil" shutdown feature which automatically shuts of the generator when it's running low on oil for self-preservation. Its 6.6 gallon tank can be filled with either propane or ...Here are some of Generac RV propane generator troubleshooting tips you should consider. 1. Confirm the fuel level. Some generators will not start at all if the fuel tank is almost empty. To solve this, you need to regularly check if the fuel level is optimal. 2. Check the spark plug. Spark plugs can wear out even if they visibly look fine.Get in touch with our support team. The generator automatically detects when the utility power is lost to the home and then begins its startup process. Once the generator is running, power is restored to the home. When utility power is restored, the generator automatically shuts itself off.Generator Runs for 90 seconds then shuts off. Generac, Guardian, Honeywell, Siemens, Centurion, Watchdog, Bryant, Olympian & Carrier Liquid Cooled Home Standby & Commercial generator troubleshooting and repair questions ... I installed the circuit breaker and the generator ran 20 minutes until I shut if off. Thank you for all your help! Top ...Most generators will run on fuel such as diesel or gas. As such, if there’s a problem that keeps the fuel from reaching the engine, then your Honda, Generac, or Briggs and Stratton generator will keep shutting off. These problems will either be in the fuel tank or the fuel pipes.The unit hadn't been used for quite a while and wasn't working, but I found the problem to be a bad battery. I replaced the battery and got the unit running. I went through checking the manual operation, then checked out the automating transfer switch operation. Everything worked great and the unit ran well. I then went to set the exercise timer.Hi my 4500 kenowa generator ( 4 yrs old )pulls starts -starts up on the ist pull but only runs a few seconds then shuts off -oil is fine, what could be the problem? ... Certified on Onan and Generac generators. Ranwell1. Small Engine Technician. 6,241 satisfied customers.Power that wasn't connected to generator is on. Generator is off and no power to the currents it was connected to ... ( generac) 15k Generator it shut down with a overspeed fault now it will start and run 15 sec then shut down and try again. The generator may shut off if it is under too much load if the fuel shut-off valve is engaged, or if the oil level is low. If it shuts down after 4 seconds then it is likely the low oil pressure switch. If it shuts down after 2 seconds, then likely it is the rpm sensor on the flywheel. It can go bad or go out of adjustment. Check the sensor output while running , even if only 2 secs, you should get 0.4-0.6 v AC and the sensor should have 1000 ohms +- 10 % resistance.To turn the generator OFF: Set the main utility disconnect to OFF (OPEN) Set the generator MLCB (generator disconnect) to OFF (OPEN). Allow the generator to run for …At the controller, set the generator to OFF. Remove the 7.5A fuse from the controller. To turn the generator back ON: Install 7.5A fuse in controller. Confirm the generator MLCB (generator disconnect) is OFF (OPEN). At the controller, set the generator to AUTO mode. Generator will start and run. Allow generator to run and warm up for a few ...Generac Generator Troubleshooting, Help, and Repair Forum | Gentek Power. ... then shuts off until the generator is up to full speed, then it switches to generator power and runs fine after that. Any help? Top. Chris Site Admin Posts: 7366 Joined: Sun Aug 05, 2018 12:46 amA Honda generator may start and then die due to a plugged air filter, wrong choke setting, clogged fuel line, plugged fuel filter, dirty carburetor, bad gas cap, dirty spark plug, faulty ignition coil, low engine oil level, or old gasoline. Follow all safety precautions listed in the Honda operator's manual.Most generators will run on fuel such as diesel or gas. As such, if there’s a problem that keeps the fuel from reaching the engine, then your Honda, Generac, or Briggs and Stratton generator will keep …

I have a Generac Generator, Model 09777-1, series 4000XL (Engine Ident. # XXXXX 00951-0) The engine starts easily with one or two pulls, runs normally for about 15 seconds then proptly shuts off. Chok … read more. The shift showtimes near marcus oakdale cinema

generac generator runs then shuts off

A Honda generator may start and then die due to a plugged air filter, wrong choke setting, clogged fuel line, plugged fuel filter, dirty carburetor, bad gas cap, dirty spark plug, faulty ignition coil, low engine oil level, or old gasoline. Follow all safety precautions listed in the Honda operator’s manual.I have a 14KW generac generator with an automatic transfer switch to control my sump pumps during a power outage. Model 0055300 serial 5036675 I have an issue during startup, it revs super high and shuts down, after doing this a couple times it gives me the RPM SENSE LOSS code.Generator Runs for a Few Minutes Then Stops – Possible Reasons & Solutions. 1. Overloading. Without a doubt, the most common reason for a generator to …Here's what I've been buying this week. Try not get burned, and generate above market returns. Here's what I've been buying this week....HOOD You run toward the fir...4. Oil Level. If the oil levels are too low, your generator can go off. Though generators can still start with low oil, new models have low oil shut-off sensors to shut off the engine automatically. Also, running the generator with no oil or low oil can wear and destroy various engine parts. At the controller, set the generator to OFF. Remove the 7.5A fuse from the controller. To turn the generator back ON: Install 7.5A fuse in controller. Confirm the generator MLCB (generator disconnect) is OFF (OPEN). At the controller, set the generator to AUTO mode. Generator will start and run. Allow generator to run and warm up for a few ... Is the generator's main line breaker in the ON position? If the breaker is turned off, the generator will not be able to transfer power from the generator to the home. Is the control board on the generator working? If not, there could be battery failure, or the cables could be loose or defective. Generac generators use a Group 26R, 12-volt 540 ...Solution: Check your oil levels; keeping the optimal oil levels can solve this problem and help your generator’s smooth functioning. Here’re the best generator engine oils on the market to buy, do check …Help. I have a Generac 56060 XP8000 Model generator. After about 20 minutes of run time it shuts off. It starts smoothly and appears to run smoothly. I have tried everything. It has gas and plenty of … read more4. Oil Level. If the oil levels are too low, your generator can go off. Though generators can still start with low oil, new models have low oil shut-off sensors to shut off the engine automatically. Also, running the generator with no oil or low oil can wear and destroy various engine parts.Generac Guardian 15000 Watt whole house standby generator was running fine then shut down instead oversteer started it - Answered by a verified Technician ... I have a 10 KW generac standby generator runs for 10 to 20 seconds and then shuts off on LP does not start when I switch it to ... I have a Generac Guardian 15 KW generator that runs but ...Last Friday the test cycle ran fine as it does every week. Last night we had a 30 second power failure, the generator started and shut down. Then a real power failure due to the storms... The Generator ran for about 20 seconds and shut down. Oil Low and Battery low lights were on. So I added 1/2 quart oil in the dark.I have a Generac 5525 20,000 air cooled stand by generator that runs on natural gas. This was purchased from and installed by an authorized Generac dealer not quite 2 years ago. It had its 1 year main …Allow the generator to run for a cool-down period of approximately one minute. At the controller, set the generator to OFF. Remove the 7.5A fuse from the controller. To turn the generator back ON: Install 7.5A fuse in controller. Confirm the generator MLCB (generator disconnect) is OFF (OPEN). At the controller, set the generator to AUTO mode.Generac generator running then shutting off can have various causes, including overload, fuel and oil levels, water levels, choke position, rodent or animal …have a generac GN-360/NP-50G, Model 09712-3 in a 1997 gulfstream RV The generator starts up and seems to run fine, however, I only have power to the RV for about 5 seconds, then the power shuts off, the generator keeps running, then in about 20 seconds we get power again for about 5 seconds, then the power shuts off, in about 20 seconds we get power again for about 5 seconds, then the power ...Mar 5, 2021 · Gas line will be changed to 3/4 " in to gen, with the Generac vibration line then a 36" x 3/4 pipe to 2nd stage regulator. When gen runs for 10 seconds the flow of gas is 10.5" w.c and the RPM is steady Posted 12/21/2013 19:43 (#3536955 - in reply to #3536709) Subject: Re: Generac Generator shutting off after startup. Faunsdale, AL. Could be any one of several things, but most likely a bad circuit board, broken wire etc. They will also shut down like that from low oil pressure, (usually has to time out a delay ), no AC voltage build up ... Your Generator Runs Then Shuts Off & Won’t Stay Running 1. Gas Tank is Empty. A gas-powered generator won’t run without gas. I only mention this common knowledge fact because you may be frustrated and skipped checking this obvious reason. Look for a fuel leak causing you to consume fuel quicker than usual. A Generac generator starts and then dies due to an empty fuel tank, plugged fuel filter, dirty carburetor, clogged fuel line, bad gas cap, dirty spark plug, faulty ignition coil, low engine oil level, or old gas. Learn how to diagnose and fix these 12 problems with easy steps and tips.My 22kw Generac Generator will NOT shut off. I've tried absolutely everything including checking and pulling the fuses. The generator still would not shut off. ... Although this is a maybe since if it's in a spot where it will run, it would run without the stepper moving Choke off (also powered by the controller).